Sample File	C:\Users\Jake\Desktop\AIM Raw\14-8-4 Test Data.S80
Classifier Model	3080
DMA Model	3081
DMA Inner Radius(cm)	0.00937
DMA Outer Radius(cm)	0.01961
DMA Characteristic Length(cm)	0.44369
CPC Model	3775 High Flow
Reference Gas Viscosity (Pa*s)	1.83245e-005
Reference Mean Free Path (m)	6.73e-008
Reference Gas Temperature (K)	296.15
Reference Gas Pressure (kPa)	101.3
Channels/Decade	64
Multiple Charge Correction	TRUE
Nanoparticle Aggregate Mobility Analysis	FALSE
Diffusion Correction	TRUE
Gas Density	0.0012
Units	Concentration (DW)
Weight	Number
Sample #	54
Date	08/04/14
Start Time	11:47:49
Diameter Midpoint
 11.3	469659
 11.8	446525
 12.2	437247
 12.6	457992
 13.1	484745
 13.6	507828
 14.1	522761
 14.6	556871
 15.1	580989
 15.7	607273
 16.3	635746
 16.8	663677
 17.5	693617
 18.1	721716
 18.8	743442
 19.5	772856
 20.2	799180
 20.9	807702
 21.7	825475
 22.5	842008
 23.3	856949
 24.1	866008
 25.0	868234
 25.9	871644
 26.9	866314
 27.9	845076
 28.9	814841
 30.0	768074
 31.1	719163
 32.2	669229
 33.4	608259
 34.6	556948
 35.9	497543
 37.2	440605
 38.5	383754
 40.0	336064
 41.4	286202
 42.9	243922
 44.5	206394
 46.1	175621
 47.8	148043
 49.6	123156
 51.4	101751
 53.3	84781.2
 55.2	70295
 57.3	57151.4
 59.4	46170.4
 61.5	37076.6
 63.8	29970
 66.1	23164.9
 68.5	18241.6
 71.0	14558.4
 73.7	12554
 76.4	11360.8
 79.1	10529.8
 82.0	10421.3
 85.1	9608.26
 88.2	8318.08
 91.4	7110.1
 94.7	5710.05
 98.2	4536.24
101.8	3928.2
105.5	3181.16
109.4	2711.84
113.4	2043.47
117.6	1552.73
121.9	1306.21
126.3	1015.54
131.0	697.689
135.8	612.684
140.7	473.622
145.9	443.874
151.2	344.363
156.8	303.687
162.5	233.222
168.5	212.292
174.7	164.518
181.1	146.508
187.7	154.932
194.6	96.9676
201.7	136.602
209.1	97.2214
216.7	90.71
224.7	96.7479
232.9	66.6886
241.4	74.7188
250.3	66.6238
259.5	58.0078
269.0	64.9733
278.8	65.6332
289.0	53.4525
299.6	68.0392
310.6	44.7797
322.0	42.2321
333.8	47.9431
346.0	55.9595
358.7	35.6689
371.8	44.9252
385.4	29.0716
399.5	46.1421
414.2	42.9776
429.4	33.3137
445.1	14.684
461.4	14.8377
478.3	16.0405
Scan Up Time(s)	120
Retrace Time(s)	15
Down Scan First	FALSE
Scans Per Sample	1
Impactor Type(cm)	0.071
Sheath Flow(lpm)	5
Aerosol Flow(lpm)	0.5
CPC Inlet Flow(lpm)	1.5
CPC Sample Flow(lpm)	0.3
Low Voltage	10.7256
High Voltage	9980.98
Lower Size(nm)	11.1397
Upper Size(nm)	486.968
Density(g/cc)	1
Title	
Status Flag	Normal Scan
td(s)	2.258
tf(s)	4.51249
D50(nm)	1081.44
Median(nm)	22.9572
Mean(nm)	24.8328
Geo. Mean(nm)	22.96
Mode(nm)	25.9455
Geo. Std. Dev.	1.47501
Total Concentration(#/cm)	2.53137e+007
Comment	